RDS3 auto transfer switch has 4 sizes, which are 63A, 125A, 250A, 630A. RDS3 is developed by our own R&D team, featured with elegant outlook and distinguished design.
Quantity: | |
---|---|
RDS3-125 Motorized Changeover Switch 100 Amp Automatic Transfer Switches
RDS3 auto transfer switch has 4 sizes, which are 63A, 125A, 250A, 630A. RDS3 is developed by our own R&D team, featured with elegant outlook and distinguished design. RDS3 has built-in B/E control modules (optional). Working voltage can be customized to: 120V/208V/230V/400V/440V/460V/480V 50Hz/50Hz.
RDS3-125B:
Optional Accessories:
- LCD display is connected by a 2 meter data cable to the control module.
- Module G, provide DC12/24V control signal to work with a ATS or genset controller, e.g. DSE controller, ComAp controller etc.
RDS3-125 Technical Data:
RDS3-125 | ||
Rated Working current (A) le | 125A | |
Rated Insulation voltage (V) Ui | 800 | |
Rated impulse withstand voltage (KV) Uimp | 8 | |
Rated short time withstand current (KA, rms) Icw | 10KA (200MS) | |
Rated short circuit making capacity (KA, peak) Icm | 20KA | |
Rated limit short circuit current (KA) Iq | 120kA | |
Rated control power supply voltage (V) Us | 230V | |
Contact transfer time (s) | 1 | |
Operation cycles (times) | Mechanical life | 8500 |
Electrical life | 1500 | |
Total | 10000 | |
Outline size (mm) WxDxH | 245×130×122 | |
Weight (kg) | 5 |
RDS3 Control Module Features:
Pictures | ||
Model | RDS3-B | RDS3-E |
Control power voltage | AC230V | |
Operating mode | Auto/Manual | Auto/Manual |
Source priority | Default source I priority | Source I priority/Source II priority/no priority. |
Mechanical isolation lock | Yes | |
Generator control | Generator starter signal | Generator start and stop timer |
Fire linkage | Yes ( Forced 0 position) | |
Working status indicator | LED: Running status LED indicator for I/II POWER source and I/II ON/OFF status | LED: Running status LED indicator for I/II POWER source and I/II ON/OFF status LCD: Settable keyboard and voltage, frequency, display. |
Controller features | Three phase over/under voltage monitoring | Set I/II/NO source priority, over/low-voltage value, over/under frequency value, transfer time delay, weekly/ monthly/ engine exerciser. |
Power monitoring | ABC three phase over-voltage 265V ABC three phase low-voltage 187V ABC three phase voltage missing monitor | ABC three phase over-voltage (240-290V adjustable) ABC three phase under-voltage (150 operation -200V adjustable) ABC three phase voltage missing monitor |
Delay time | Default 5s. | Transfer delay timer (0-300s adjustable) Recovery delay timer (0-300s adjustable) Generator start, stop delay timer (0-300s adjustable) |
Note:
1. LCD display is optional at RDS3-B, with LCD, same functions with E module, and all parameters becomes settable.
2. ATS Transfer to "0" position when I or II power both fails. On the condition that A phase is normal, B or C phase loss, over or under voltage, over or under frequency, note, if A phase loss, this function not available, ATS must have power supply to enable it's motor.
RDS3 Series
PC Class Automatic Transfer Switch
63 Amp Automatic Transfer Switches have smaller size and is easy to install, space saving;
10Ie making and breaking capacity, reach AC-33B utilization category; with multifunction intelligent controller, programmable high/low voltage protection, high/low frequency protection, adjustable transfer delay time, adjustable center delay time, build-in engine exerciser, fault transfer to “0" function is optional;
Removable LCD display, to match different installation requirements; Frame current: 125A, 250A, 630A
Hot Tags: 63 amp automatic transfer switches, China 63 amp automatic transfer switches, 63 amp automatic transfer switches suppliers, 63 amp automatic transfer switches manufacturers, 63 amp automatic transfer switches factory, 63 amp automatic transfer switches price
RDS3-125 Motorized Changeover Switch 100 Amp Automatic Transfer Switches
RDS3 auto transfer switch has 4 sizes, which are 63A, 125A, 250A, 630A. RDS3 is developed by our own R&D team, featured with elegant outlook and distinguished design. RDS3 has built-in B/E control modules (optional). Working voltage can be customized to: 120V/208V/230V/400V/440V/460V/480V 50Hz/50Hz.
RDS3-125B:
Optional Accessories:
- LCD display is connected by a 2 meter data cable to the control module.
- Module G, provide DC12/24V control signal to work with a ATS or genset controller, e.g. DSE controller, ComAp controller etc.
RDS3-125 Technical Data:
RDS3-125 | ||
Rated Working current (A) le | 125A | |
Rated Insulation voltage (V) Ui | 800 | |
Rated impulse withstand voltage (KV) Uimp | 8 | |
Rated short time withstand current (KA, rms) Icw | 10KA (200MS) | |
Rated short circuit making capacity (KA, peak) Icm | 20KA | |
Rated limit short circuit current (KA) Iq | 120kA | |
Rated control power supply voltage (V) Us | 230V | |
Contact transfer time (s) | 1 | |
Operation cycles (times) | Mechanical life | 8500 |
Electrical life | 1500 | |
Total | 10000 | |
Outline size (mm) WxDxH | 245×130×122 | |
Weight (kg) | 5 |
RDS3 Control Module Features:
Pictures | ||
Model | RDS3-B | RDS3-E |
Control power voltage | AC230V | |
Operating mode | Auto/Manual | Auto/Manual |
Source priority | Default source I priority | Source I priority/Source II priority/no priority. |
Mechanical isolation lock | Yes | |
Generator control | Generator starter signal | Generator start and stop timer |
Fire linkage | Yes ( Forced 0 position) | |
Working status indicator | LED: Running status LED indicator for I/II POWER source and I/II ON/OFF status | LED: Running status LED indicator for I/II POWER source and I/II ON/OFF status LCD: Settable keyboard and voltage, frequency, display. |
Controller features | Three phase over/under voltage monitoring | Set I/II/NO source priority, over/low-voltage value, over/under frequency value, transfer time delay, weekly/ monthly/ engine exerciser. |
Power monitoring | ABC three phase over-voltage 265V ABC three phase low-voltage 187V ABC three phase voltage missing monitor | ABC three phase over-voltage (240-290V adjustable) ABC three phase under-voltage (150 operation -200V adjustable) ABC three phase voltage missing monitor |
Delay time | Default 5s. | Transfer delay timer (0-300s adjustable) Recovery delay timer (0-300s adjustable) Generator start, stop delay timer (0-300s adjustable) |
Note:
1. LCD display is optional at RDS3-B, with LCD, same functions with E module, and all parameters becomes settable.
2. ATS Transfer to "0" position when I or II power both fails. On the condition that A phase is normal, B or C phase loss, over or under voltage, over or under frequency, note, if A phase loss, this function not available, ATS must have power supply to enable it's motor.
RDS3 Series
PC Class Automatic Transfer Switch
63 Amp Automatic Transfer Switches have smaller size and is easy to install, space saving;
10Ie making and breaking capacity, reach AC-33B utilization category; with multifunction intelligent controller, programmable high/low voltage protection, high/low frequency protection, adjustable transfer delay time, adjustable center delay time, build-in engine exerciser, fault transfer to “0" function is optional;
Removable LCD display, to match different installation requirements; Frame current: 125A, 250A, 630A
Hot Tags: 63 amp automatic transfer switches, China 63 amp automatic transfer switches, 63 amp automatic transfer switches suppliers, 63 amp automatic transfer switches manufacturers, 63 amp automatic transfer switches factory, 63 amp automatic transfer switches price
content is empty!